ISO/TR TECHNICAL REPORT 10295-3 First edition 2012-08-01 Fire tests for building elements and components Fire testing of service installations - Part 3: Single component penetration seals Guidance on the construction and use of test configurations and simulated services to characterise sealing materials Essais au feu pour les éléments et composants de batiment-Essai au feu des installations de service- Partie 3:Joints depenetrationa composant unique-Lignes directrices sur la construction et I'utilisation des configurations d'essai et des processus de simulation permettant de caracteriser les materiaux d'etancheite Reference number ISO/TR 10295-3:2012(E) TSO @ ISO 2012 license from IHS Not for Resale ISO/TR 10295-3:2012(E) COPYRIGHTPROTECTEDDOCUMENT ISO2012 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 · CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail
[email protected] Web www.iso.org Published in Switzerland @ ISO 2012 -All rights reserved y IHS unde etworking permitted without license from IHS Not for Resale ISO/TR 10295-3:2012(E) Contents Page Foreword ..iv Introduction 1 Scope. 2 Normative references 2 3 Terms and definitions. .2 4 Test equipment. 3 5 General performance criteria. .3 6 Guidance on test configurations and procedures 4 7 Test procedures.. 7.1 5 7.2 Test configuration B - Thermal diffusity of the conductor / penetration. 6 7.3 Test configuration C. 7.4 Test configuration D - When multiple simulated services are being tested 8 7.5 Test procedure E 7.6 Test procedure F 8 7.7 Test procedure G 9 7.8 Test procedure H. 8 Deriving the field of application by judgemental analysis 9 8.1 Analysis using test configuration A 9 8.2 Analysis using test configuration B 9 8.3 Analysis using test configuration C. 8.4 Analysis using test configuration D. 10 9 Deriving the field of application by mathematical analysis 9.1 Use of the 3-D interpolation method to predict the extended field of application. .10 Annex A (informative) Determining the extended field of application.... Annex B (informative)Exampleof the application of the principles of 3-D interpolation to the establishment of the extended application of penetrating sealing system.. 13 Annex C (informative) 3-D interpolation method of analysis. 16 ili cense from IHS Not for Resale
ISO TR 10295-3 2012 Fire tests for building elements and components — Fire testing of service installations — Part 3 Single component penetration seals — Guidance on the construction
文档预览
中文文档
27 页
50 下载
1000 浏览
0 评论
309 收藏
3.0分
温馨提示:本文档共27页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
本文档由 人生无常 于 2024-08-31 16:51:05上传分享